Fleet health
Dirk Siebels
Healthy26931 Elsfleth · 4.67 kWp · Kostal PLENTICORE plus 4.2 (4.2 kW) · data from KOSTAL Solar Portal · S-0310
Result of the last 14 days
Behaves like a healthy inverter
Health score
1003.4 yrs
inverter age
Installed 15 Jun 2023
1 %
failure risk, next 12 months
Age curve from field data, adjusted by health
19 months
warranty left
5 years, ends 15 Jun 2028
17.1 years
EEG payment left
8.20 ct/kWh until 31 Dec 2043
Physics checks
Six rule families on the last 14 days of 5-minute values. No training data involved.
- Operating state and limitsNo feed-in during 0.0 % of sunny samples · grid 225–235 V · heat sink max 33 °C
- Power balanceConversion efficiency 96.7 % · −0.52 points extra loss vs datasheet curve
- Thermal behaviour0.0 % of loaded samples hotter than the thermal model allows
- Irradiance consistencyPerformance ratio 94 % (expected 70–100 %)
- DC-side stabilityRipple 0.94× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
- Data quality99.4 % of expected samples received (1,250 values)
AI model
Fault class from the gap between measured values and the LSTM's healthy prediction.
- Healthy97.1 %
- Capacitor aging0 %
- Cooling fault2.1 %
- IGBT degradation0 %
- MPPT fault0 %
- Hard fault0.8 %
Evidence check
No alertHealthy
The AI model raised no alert.
Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.