Demo with a simulated fleet: customers are invented and inverter data comes from a physics simulator. The analysis and the AI model run live on that data.

How it works

The steps behind every early warning, and how the models in this demo perform on held-out test data.

  1. 1Inverter data

    5-minute values from any brand portal: DC and AC power, DC voltage, temperature, grid values.

  2. 2Physics checks

    Six rule families: operating limits, power balance, thermal behaviour, irradiance consistency, DC-side stability, data quality.

  3. 3AI model

    An LSTM learns how a healthy inverter behaves. A classifier names the fault from the gap between prediction and measurement.

  4. 4Evidence check

    An AI alert is compared with the physics checks: confirmed, contradicted or not yet visible.

  5. 5Early warning

    Consistent, inconsistent or inconclusive. Only then does a customer appear on the contact list.

What these numbers are. Both models were trained and tested on data from a physics simulator calibrated to residential string inverters, because labelled failure data from real fleets does not exist yet in one place. Simulated faults are cleaner than real ones, so results on real inverters will be lower. Validation on real pilot-fleet data is planned through March 2027.

Healthy-behaviour model (LSTM)

2,275 days
healthy training data
359,829 five-minute samples incl. validation
±1.6 K
heat-sink temperature error
Mean absolute error, validation days
±0.65 %
DC voltage error
±0.08 %
conversion loss error
In percent of rated power

16 LSTM units, 1,412 parameters. Small on purpose: it runs on every inverter of a fleet in a serverless function, without a GPU.

Fault classifier, six classes

98.2 %
accuracy on test windows
1,800 windows never seen in training
2.4 %
false alarms on healthy inverters
Before the evidence check filters them
94 %
detected at 10–25 % progression
The earliest, weakest stage
±5 pts
progression estimate error

Confusion matrix (rows: true class, columns: predicted)

HealthyCapacitor agingCooling faultIGBT degradationMPPT faultHard faultRecall
Healthy51531050096.6 %
Capacitor aging1260000099.6 %
Cooling fault8024000096.8 %
IGBT degradation2012500098.8 %
MPPT fault00002520100.0 %
Hard fault2100025098.8 %

Detection rate by fault progression

  • 10–25 %94 %
  • 25–40 %100 %
  • 40–60 %100 %
  • 60–80 %100 %
  • 80–100 %100 %

Share of faulty test windows flagged with at least 60 % confidence. Trained on 7,200 14-day windows.

Failure risk by age

The 12-month failure risk on each system page starts from a Weibull age curve fitted to a field study (Bucher, Wandel & Joss, BFH 2022: 34.3 % of residential inverters had a first failure within 15 years) and is raised when the analysis reports a confirmed early warning. With every connected installer the curve can be fitted per brand and model.