How it works
The steps behind every early warning, and how the models in this demo perform on held-out test data.
- 1Inverter data
5-minute values from any brand portal: DC and AC power, DC voltage, temperature, grid values.
- 2Physics checks
Six rule families: operating limits, power balance, thermal behaviour, irradiance consistency, DC-side stability, data quality.
- 3AI model
An LSTM learns how a healthy inverter behaves. A classifier names the fault from the gap between prediction and measurement.
- 4Evidence check
An AI alert is compared with the physics checks: confirmed, contradicted or not yet visible.
- 5Early warning
Consistent, inconsistent or inconclusive. Only then does a customer appear on the contact list.
What these numbers are. Both models were trained and tested on data from a physics simulator calibrated to residential string inverters, because labelled failure data from real fleets does not exist yet in one place. Simulated faults are cleaner than real ones, so results on real inverters will be lower. Validation on real pilot-fleet data is planned through March 2027.
Healthy-behaviour model (LSTM)
16 LSTM units, 1,412 parameters. Small on purpose: it runs on every inverter of a fleet in a serverless function, without a GPU.
Fault classifier, six classes
Confusion matrix (rows: true class, columns: predicted)
| Healthy | Capacitor aging | Cooling fault | IGBT degradation | MPPT fault | Hard fault | Recall | |
|---|---|---|---|---|---|---|---|
| Healthy | 515 | 3 | 10 | 5 | 0 | 0 | 96.6 % |
| Capacitor aging | 1 | 260 | 0 | 0 | 0 | 0 | 99.6 % |
| Cooling fault | 8 | 0 | 240 | 0 | 0 | 0 | 96.8 % |
| IGBT degradation | 2 | 0 | 1 | 250 | 0 | 0 | 98.8 % |
| MPPT fault | 0 | 0 | 0 | 0 | 252 | 0 | 100.0 % |
| Hard fault | 2 | 1 | 0 | 0 | 0 | 250 | 98.8 % |
Detection rate by fault progression
- 10–25 %94 %
- 25–40 %100 %
- 40–60 %100 %
- 60–80 %100 %
- 80–100 %100 %
Share of faulty test windows flagged with at least 60 % confidence. Trained on 7,200 14-day windows.
Failure risk by age
The 12-month failure risk on each system page starts from a Weibull age curve fitted to a field study (Bucher, Wandel & Joss, BFH 2022: 34.3 % of residential inverters had a first failure within 15 years) and is raised when the analysis reports a confirmed early warning. With every connected installer the curve can be fitted per brand and model.