Demo with a simulated fleet: customers are invented and inverter data comes from a physics simulator. The analysis and the AI model run live on that data.
Fleet health

Meike Bruns

Healthy

26197 Großenkneten · 5.39 kWp · Kostal PLENTICORE plus 5.5 (5.5 kW) · data from KOSTAL Solar Portal · S-0307

Result of the last 14 days
Behaves like a healthy inverter
Health score
99
3.3 yrs
inverter age
Installed 18 Aug 2023
1 %
failure risk, next 12 months
Age curve from field data, adjusted by health
21 months
warranty left
5 years, ends 18 Aug 2028
17.1 years
EEG payment left
8.20 ct/kWh until 31 Dec 2043

Physics checks

Six rule families on the last 14 days of 5-minute values. No training data involved.

  • Operating state and limits
    No feed-in during 0.0 % of sunny samples · grid 226–236 V · heat sink max 31 °C
  • Power balance
    Conversion efficiency 96.3 % · −0.16 points extra loss vs datasheet curve
  • Thermal behaviour
    0.0 % of loaded samples hotter than the thermal model allows
  • Irradiance consistency
    Performance ratio 86 % (expected 70–100 %)
  • DC-side stability
    Ripple 1.06× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
  • Data quality
    100.0 % of expected samples received (1,257 values)

AI model

Fault class from the gap between measured values and the LSTM's healthy prediction.

  • Healthy90.7 %
  • Capacitor aging0 %
  • Cooling fault8.5 %
  • IGBT degradation0 %
  • MPPT fault0 %
  • Hard fault0.8 %

Evidence check

No alertHealthy

The AI model raised no alert.

Daily drift from healthy behaviour

Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.

5-minute values

14.1 kWh that day
AC power (kW)
Conversion efficiency (%)
Heat-sink temperature (°C)
DC voltage (V)
DC ripple (% of DC voltage)