Fleet health
Torsten Thaden
Healthy26203 Wardenburg · 9.36 kWp · Kostal PLENTICORE plus 8.5 (8.5 kW) · data from KOSTAL Solar Portal · S-0299
Result of the last 14 days
Behaves like a healthy inverter
Health score
1004.4 yrs
inverter age
Installed 19 Jun 2022
2 %
failure risk, next 12 months
Age curve from field data, adjusted by health
7 months
warranty left
5 years, ends 19 Jun 2027
16.1 years
EEG payment left
6.62 ct/kWh until 31 Dec 2042
Physics checks
Six rule families on the last 14 days of 5-minute values. No training data involved.
- Operating state and limitsNo feed-in during 0.0 % of sunny samples · grid 225–235 V · heat sink max 32 °C
- Power balanceConversion efficiency 96.0 % · +0.05 points extra loss vs datasheet curve
- Thermal behaviour0.0 % of loaded samples hotter than the thermal model allows
- Irradiance consistencyPerformance ratio 90 % (expected 70–100 %)
- DC-side stabilityRipple 1.01× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
- Data quality99.8 % of expected samples received (1,254 values)
AI model
Fault class from the gap between measured values and the LSTM's healthy prediction.
- Healthy98.3 %
- Capacitor aging0 %
- Cooling fault1.6 %
- IGBT degradation0 %
- MPPT fault0 %
- Hard fault0 %
Evidence check
No alertHealthy
The AI model raised no alert.
Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.