Fleet health
Tanja Frerichs
Healthy26160 Bad Zwischenahn · 5.05 kWp · Fronius Symo GEN24 5.0 Plus (5.0 kW) · data from Solar.web · S-0289
Result of the last 14 days
Behaves like a healthy inverter
Health score
100Suggested contact: Service contract. The manufacturer warranty on the Fronius Symo GEN24 5.0 Plus ends in 5 months. Offer a final check and a service contract while repairs are still covered.
- Warranty ends on 23 Apr 2027. Anything found before that date is repaired at the manufacturer's cost.
- A check now plus a service contract (€149 per year) keeps the system watched after the warranty.
- Ask Fronius about a warranty extension: usually only possible before the end date.
4.6 yrs
inverter age
Installed 23 Apr 2022
2 %
failure risk, next 12 months
Age curve from field data, adjusted by health
5 months
warranty left
5 years, ends 23 Apr 2027
16.1 years
EEG payment left
6.74 ct/kWh until 31 Dec 2042
Physics checks
Six rule families on the last 14 days of 5-minute values. No training data involved.
- Operating state and limitsNo feed-in during 0.0 % of sunny samples · grid 227–236 V · heat sink max 32 °C
- Power balanceConversion efficiency 96.7 % · +0.29 points extra loss vs datasheet curve
- Thermal behaviour0.0 % of loaded samples hotter than the thermal model allows
- Irradiance consistencyPerformance ratio 91 % (expected 70–100 %)
- DC-side stabilityRipple 0.94× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
- Data quality100.0 % of expected samples received (1,257 values)
AI model
Fault class from the gap between measured values and the LSTM's healthy prediction.
- Healthy99.2 %
- Capacitor aging0 %
- Cooling fault0 %
- IGBT degradation0.6 %
- MPPT fault0 %
- Hard fault0 %
Evidence check
No alertHealthy
The AI model raised no alert.
Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.