Early warning26135 Oldenburg · 9.41 kWp · Huawei SUN2000-8KTL-M1 (8.0 kW) · data from FusionSolar · S-0243
Suggested contact: Warranty claim + service visit. MPPT fault pattern, confirmed by physics checks on the 7-year-old Huawei SUN2000-8KTL-M1. Estimated chance of failure within 12 months: 22 %. Yield is already down 14 %, about €260 per year. Warranty runs until May 2029: claim before it ends.
- The system currently delivers 14 % less than six weeks ago under the same sun: about €260 per year if nothing is done. The household buys the missing electricity from the grid, so it shows up on the electricity bill.
- The inverter still works. The customer has noticed nothing, so there is no pressure in the call.
- Found before the warranty ends (May 2029): the repair costs the customer nothing.
- Bring the evidence: the system page shows measured against expected values.
Physics checks
Six rule families on the last 14 days of 5-minute values. No training data involved.
- Operating state and limitsNo feed-in during 0.0 % of sunny samples · grid 227–236 V · heat sink max 30 °C
- Power balanceConversion efficiency 97.8 % · −0.24 points extra loss vs datasheet curve
- Thermal behaviour0.0 % of loaded samples hotter than the thermal model allows
- Irradiance consistencyPerformance ratio 76 % (expected 70–100 %)
- DC-side stabilityRipple 1.23× nominal · 100.0 % of samples more than 6 % off the expected MPP voltage
- Data quality100.0 % of expected samples received (1,257 values)
AI model
Fault class from the gap between measured values and the LSTM's healthy prediction.
- Healthy0 %
- Capacitor aging0 %
- Cooling fault0 %
- IGBT degradation0 %
- MPPT fault100 %
- Hard fault0 %
Estimated progression: 80 % of the way to failure-level symptoms.
Evidence check
Physics checks confirm the AI alert.
Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.