Fleet health
Bernd Poppen
Healthy27798 Hude · 9.87 kWp · Fronius Symo 8.2-3-M (8.2 kW) · data from Solar.web · S-0214
Result of the last 14 days
Behaves like a healthy inverter
Health score
969.0 yrs
inverter age
Installed 24 Nov 2017
3 %
failure risk, next 12 months
Age curve from field data, adjusted by health
Expired
warranty left
7 years, ends 24 Nov 2024
11.1 years
EEG payment left
12.21 ct/kWh until 31 Dec 2037
Physics checks
Six rule families on the last 14 days of 5-minute values. No training data involved.
- Operating state and limitsNo feed-in during 0.0 % of sunny samples · grid 227–235 V · heat sink max 39 °C
- Power balanceConversion efficiency 97.6 % · −0.19 points extra loss vs datasheet curve
- Thermal behaviour0.0 % of loaded samples hotter than the thermal model allows
- Irradiance consistencyPerformance ratio 88 % (expected 70–100 %)
- DC-side stabilityRipple 0.86× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
- Data quality99.7 % of expected samples received (1,253 values)
AI model
Fault class from the gap between measured values and the LSTM's healthy prediction.
- Healthy62.0 %
- Capacitor aging0 %
- Cooling fault36.2 %
- IGBT degradation1.7 %
- MPPT fault0 %
- Hard fault0 %
Evidence check
No alertHealthy
The AI model raised no alert.
Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.