Fleet health
Hauke Kruse
Healthy26919 Brake · 6.17 kWp · SMA Sunny Tripower 6.0 (6.0 kW) · data from Sunny Portal · S-0207
Result of the last 14 days
Behaves like a healthy inverter
Health score
969.9 yrs
inverter age
Installed 12 Dec 2016
4 %
failure risk, next 12 months
Age curve from field data, adjusted by health
Expired
warranty left
5 years, ends 12 Dec 2021
10.1 years
EEG payment left
12.31 ct/kWh until 31 Dec 2036
Physics checks
Six rule families on the last 14 days of 5-minute values. No training data involved.
- Operating state and limitsNo feed-in during 0.0 % of sunny samples · grid 226–235 V · heat sink max 38 °C
- Power balanceConversion efficiency 97.3 % · +0.06 points extra loss vs datasheet curve
- Thermal behaviour0.0 % of loaded samples hotter than the thermal model allows
- Irradiance consistencyPerformance ratio 90 % (expected 70–100 %)
- DC-side stabilityRipple 1.15× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
- Data quality100.0 % of expected samples received (1,257 values)
AI model
Fault class from the gap between measured values and the LSTM's healthy prediction.
- Healthy26.9 %
- Capacitor aging1.0 %
- Cooling fault72.0 %
- IGBT degradation0 %
- MPPT fault0 %
- Hard fault0 %
Evidence check
No alertHealthy
The AI model raised no alert.
Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.