Fleet health
Karin Hoffmann
Healthy26316 Varel · 6.78 kWp · SolarEdge SE6K (6.0 kW) · data from SolarEdge Monitoring · S-0202
Result of the last 14 days
Behaves like a healthy inverter
Health score
10010.9 yrs
inverter age
Installed 27 Dec 2015
4 %
failure risk, next 12 months
Age curve from field data, adjusted by health
13 months
warranty left
12 years, ends 27 Dec 2027
9.1 years
EEG payment left
12.31 ct/kWh until 31 Dec 2035
Physics checks
Six rule families on the last 14 days of 5-minute values. No training data involved.
- Operating state and limitsNo feed-in during 0.0 % of sunny samples · grid 227–236 V · heat sink max 36 °C
- Power balanceConversion efficiency 96.5 % · +0.26 points extra loss vs datasheet curve
- Thermal behaviour0.0 % of loaded samples hotter than the thermal model allows
- Irradiance consistencyPerformance ratio 90 % (expected 70–100 %)
- DC-side stabilityRipple 0.92× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
- Data quality100.0 % of expected samples received (1,257 values)
AI model
Fault class from the gap between measured values and the LSTM's healthy prediction.
- Healthy97.9 %
- Capacitor aging0 %
- Cooling fault2.0 %
- IGBT degradation0 %
- MPPT fault0 %
- Hard fault0 %
Evidence check
No alertHealthy
The AI model raised no alert.
Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.