Demo with a simulated fleet: customers are invented and inverter data comes from a physics simulator. The analysis and the AI model run live on that data.
Fleet health

Torsten Schröder

Watch

26209 Hatten · 4.82 kWp · SMA Sunny Tripower 5000TL (5.0 kW) · data from Sunny Portal · S-0198

Result of the last 14 days
Cooling fault pattern, not yet visible to physics checks
Health score
83
10.9 yrs
inverter age
Installed 25 Dec 2015
6 %
failure risk, next 12 months
Age curve from field data, adjusted by health
Expired
warranty left
5 years, ends 25 Dec 2020
9.1 years
EEG payment left
12.31 ct/kWh until 31 Dec 2035

Physics checks

Six rule families on the last 14 days of 5-minute values. No training data involved.

  • Operating state and limits
    No feed-in during 0.0 % of sunny samples · grid 226–235 V · heat sink max 37 °C
  • Power balance
    Conversion efficiency 97.0 % · +0.15 points extra loss vs datasheet curve
  • Thermal behaviour
    0.0 % of loaded samples hotter than the thermal model allows
  • Irradiance consistency
    Performance ratio 90 % (expected 70–100 %)
  • DC-side stability
    Ripple 1.07× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
  • Data quality
    99.5 % of expected samples received (1,251 values)

AI model

Fault class from the gap between measured values and the LSTM's healthy prediction.

  • Healthy29.1 %
  • Capacitor aging0 %
  • Cooling fault70.8 %
  • IGBT degradation0 %
  • MPPT fault0 %
  • Hard fault0 %

Estimated progression: 12 % of the way to failure-level symptoms.

Evidence check

InconclusiveWatch

The AI sees drift that the physics checks cannot confirm yet.

Daily drift from healthy behaviour

Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.

5-minute values

11.9 kWh that day
AC power (kW)
Conversion efficiency (%)
Heat-sink temperature (°C)
DC voltage (V)
DC ripple (% of DC voltage)