Fleet health
Torsten Schröder
Watch26209 Hatten · 4.82 kWp · SMA Sunny Tripower 5000TL (5.0 kW) · data from Sunny Portal · S-0198
Result of the last 14 days
Cooling fault pattern, not yet visible to physics checks
Health score
8310.9 yrs
inverter age
Installed 25 Dec 2015
6 %
failure risk, next 12 months
Age curve from field data, adjusted by health
Expired
warranty left
5 years, ends 25 Dec 2020
9.1 years
EEG payment left
12.31 ct/kWh until 31 Dec 2035
Physics checks
Six rule families on the last 14 days of 5-minute values. No training data involved.
- Operating state and limitsNo feed-in during 0.0 % of sunny samples · grid 226–235 V · heat sink max 37 °C
- Power balanceConversion efficiency 97.0 % · +0.15 points extra loss vs datasheet curve
- Thermal behaviour0.0 % of loaded samples hotter than the thermal model allows
- Irradiance consistencyPerformance ratio 90 % (expected 70–100 %)
- DC-side stabilityRipple 1.07× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
- Data quality99.5 % of expected samples received (1,251 values)
AI model
Fault class from the gap between measured values and the LSTM's healthy prediction.
- Healthy29.1 %
- Capacitor aging0 %
- Cooling fault70.8 %
- IGBT degradation0 %
- MPPT fault0 %
- Hard fault0 %
Estimated progression: 12 % of the way to failure-level symptoms.
Evidence check
InconclusiveWatch
The AI sees drift that the physics checks cannot confirm yet.
Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.