Fleet health
Karin Fischer
Healthy26188 Edewecht · 6.73 kWp · Fronius Symo 6.0-3-M (6.0 kW) · data from Solar.web · S-0185
Result of the last 14 days
Behaves like a healthy inverter
Health score
9812.1 yrs
inverter age
Installed 1 Nov 2014
5 %
failure risk, next 12 months
Age curve from field data, adjusted by health
4.9 years
warranty left
17 years, ends 1 Nov 2031
8.1 years
EEG payment left
12.69 ct/kWh until 31 Dec 2034
Physics checks
Six rule families on the last 14 days of 5-minute values. No training data involved.
- Operating state and limitsNo feed-in during 0.0 % of sunny samples · grid 226–236 V · heat sink max 34 °C
- Power balanceConversion efficiency 96.9 % · +0.25 points extra loss vs datasheet curve
- Thermal behaviour0.0 % of loaded samples hotter than the thermal model allows
- Irradiance consistencyPerformance ratio 87 % (expected 70–100 %)
- DC-side stabilityRipple 0.93× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
- Data quality99.1 % of expected samples received (1,246 values)
AI model
Fault class from the gap between measured values and the LSTM's healthy prediction.
- Healthy84.3 %
- Capacitor aging0 %
- Cooling fault2.3 %
- IGBT degradation13.3 %
- MPPT fault0 %
- Hard fault0 %
Evidence check
No alertHealthy
The AI model raised no alert.
Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.