Fleet health
Holger Hoffmann
Healthy26197 Großenkneten · 7.12 kWp · SolarMax 6000MT (6.0 kW) · data from MaxWeb · S-0179
Result of the last 14 days
Behaves like a healthy inverter
Health score
10012.9 yrs
inverter age
Installed 12 Dec 2013
5 %
failure risk, next 12 months
Age curve from field data, adjusted by health
2.1 years
warranty left
15 years, ends 12 Dec 2028
7.1 years
EEG payment left
13.88 ct/kWh until 31 Dec 2033
Physics checks
Six rule families on the last 14 days of 5-minute values. No training data involved.
- Operating state and limitsNo feed-in during 0.0 % of sunny samples · grid 225–236 V · heat sink max 32 °C
- Power balanceConversion efficiency 95.5 % · +0.20 points extra loss vs datasheet curve
- Thermal behaviour0.0 % of loaded samples hotter than the thermal model allows
- Irradiance consistencyPerformance ratio 95 % (expected 70–100 %)
- DC-side stabilityRipple 1.01× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
- Data quality99.8 % of expected samples received (1,255 values)
AI model
Fault class from the gap between measured values and the LSTM's healthy prediction.
- Healthy96.6 %
- Capacitor aging0 %
- Cooling fault0 %
- IGBT degradation3.2 %
- MPPT fault0 %
- Hard fault0 %
Evidence check
No alertHealthy
The AI model raised no alert.
Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.