Fleet health
Dirk Johannes
Healthy26655 Westerstede · 7.12 kWp · Fronius IG Plus 75 V (6.0 kW) · data from Solar.web · S-0164
Result of the last 14 days
Behaves like a healthy inverter
Health score
9713.3 yrs
inverter age
Installed 23 Aug 2013
5 %
failure risk, next 12 months
Age curve from field data, adjusted by health
Expired
warranty left
5 years, ends 23 Aug 2018
7.1 years
EEG payment left
15.02 ct/kWh until 31 Dec 2033
Physics checks
Six rule families on the last 14 days of 5-minute values. No training data involved.
- Operating state and limitsNo feed-in during 0.0 % of sunny samples · grid 226–235 V · heat sink max 31 °C
- Power balanceConversion efficiency 93.8 % · +0.15 points extra loss vs datasheet curve
- Thermal behaviour0.0 % of loaded samples hotter than the thermal model allows
- Irradiance consistencyPerformance ratio 94 % (expected 70–100 %)
- DC-side stabilityRipple 1.20× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
- Data quality99.8 % of expected samples received (1,254 values)
AI model
Fault class from the gap between measured values and the LSTM's healthy prediction.
- Healthy48.1 %
- Capacitor aging51.6 %
- Cooling fault0 %
- IGBT degradation0 %
- MPPT fault0 %
- Hard fault0 %
Evidence check
No alertHealthy
The AI model raised no alert.
Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.