Fleet health
Stefan Köster
Healthy26188 Edewecht · 4.43 kWp · SMA Sunny Boy 4000TL-21 (4.0 kW) · data from Sunny Portal · S-0143
Result of the last 14 days
Behaves like a healthy inverter
Health score
98Suggested contact: Replacement inverter. The 14-year-old SMA Sunny Boy 4000TL-21 is beyond the typical service life. Chance of failure within 12 months: 5 %. A planned swap avoids an emergency call.
- The inverter is 14 years old. In the field, about one in three fails within 15 years.
- Chance of failure in the next 12 months: 5 %.
- A planned swap costs about €1,630 and takes half a day. An unplanned failure means weeks without yield until a unit and a slot are available.
14.6 yrs
inverter age
Installed 22 Apr 2012
5 %
failure risk, next 12 months
Age curve from field data, adjusted by health
Expired
warranty left
5 years, ends 22 Apr 2017
6.1 years
EEG payment left
19.50 ct/kWh until 31 Dec 2032
Physics checks
Six rule families on the last 14 days of 5-minute values. No training data involved.
- Operating state and limitsNo feed-in during 0.0 % of sunny samples · grid 226–235 V · heat sink max 33 °C
- Power balanceConversion efficiency 95.5 % · +0.18 points extra loss vs datasheet curve
- Thermal behaviour0.0 % of loaded samples hotter than the thermal model allows
- Irradiance consistencyPerformance ratio 91 % (expected 70–100 %)
- DC-side stabilityRipple 1.18× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
- Data quality99.8 % of expected samples received (1,255 values)
AI model
Fault class from the gap between measured values and the LSTM's healthy prediction.
- Healthy80.6 %
- Capacitor aging16.2 %
- Cooling fault2.6 %
- IGBT degradation0 %
- MPPT fault0 %
- Hard fault0 %
Evidence check
No alertHealthy
The AI model raised no alert.
Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.