Fleet health
Hauke Wendt
Healthy27777 Ganderkesee · 5.79 kWp · Kostal PIKO 5.5 (5.5 kW) · data from PIKO Solar Portal · S-0121
Result of the last 14 days
Behaves like a healthy inverter
Health score
9714.0 yrs
inverter age
Installed 26 Nov 2012
5 %
failure risk, next 12 months
Age curve from field data, adjusted by health
Expired
warranty left
5 years, ends 26 Nov 2017
6.1 years
EEG payment left
17.78 ct/kWh until 31 Dec 2032
Physics checks
Six rule families on the last 14 days of 5-minute values. No training data involved.
- Operating state and limitsNo feed-in during 0.0 % of sunny samples · grid 226–235 V · heat sink max 36 °C
- Power balanceConversion efficiency 94.9 % · +0.36 points extra loss vs datasheet curve
- Thermal behaviour0.0 % of loaded samples hotter than the thermal model allows
- Irradiance consistencyPerformance ratio 92 % (expected 70–100 %)
- DC-side stabilityRipple 0.95× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
- Data quality100.0 % of expected samples received (1,257 values)
AI model
Fault class from the gap between measured values and the LSTM's healthy prediction.
- Healthy73.3 %
- Capacitor aging0 %
- Cooling fault26.7 %
- IGBT degradation0 %
- MPPT fault0 %
- Hard fault0 %
Evidence check
No alertHealthy
The AI model raised no alert.
Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.