Demo with a simulated fleet: customers are invented and inverter data comes from a physics simulator. The analysis and the AI model run live on that data.
Fleet health

Imke Lübben

Early warning

27777 Ganderkesee · 5.73 kWp · SMA Sunny Tripower 5000TL (5.0 kW) · data from Sunny Portal · S-0120

Result of the last 14 days
IGBT degradation pattern, not yet visible to physics checks
Health score
75

Suggested contact: Service visit + replacement quote. IGBT degradation pattern, not yet visible to physics checks on the 14-year-old SMA Sunny Tripower 5000TL. Estimated chance of failure within 12 months: 19 %.

  • A full failure would cost the customer about €130 for every month without production (yearly average).
  • The inverter still works. The customer has noticed nothing, so there is no pressure in the call.
  • Planned swap about €1,750 instead of an emergency call later.
  • Bring the evidence: the system page shows measured against expected values.
14.2 yrs
inverter age
Installed 16 Sept 2012
19 %
failure risk, next 12 months
Age curve from field data, adjusted by health
Expired
warranty left
5 years, ends 16 Sept 2017
6.1 years
EEG payment left
18.54 ct/kWh until 31 Dec 2032

Physics checks

Six rule families on the last 14 days of 5-minute values. No training data involved.

  • Operating state and limits
    No feed-in during 0.0 % of sunny samples · grid 225–235 V · heat sink max 42 °C
  • Power balance
    Conversion efficiency 97.1 % · +0.25 points extra loss vs datasheet curve
  • Thermal behaviour
    0.0 % of loaded samples hotter than the thermal model allows
  • Irradiance consistency
    Performance ratio 91 % (expected 70–100 %)
  • DC-side stability
    Ripple 0.95× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
  • Data quality
    100.0 % of expected samples received (1,257 values)

AI model

Fault class from the gap between measured values and the LSTM's healthy prediction.

  • Healthy0 %
  • Capacitor aging0 %
  • Cooling fault0 %
  • IGBT degradation100 %
  • MPPT fault0 %
  • Hard fault0 %

Estimated progression: 22 % of the way to failure-level symptoms.

Evidence check

InconclusiveEarly warning

The AI sees drift that the physics checks cannot confirm yet.

Daily drift from healthy behaviour

Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.

5-minute values

15.2 kWh that day
AC power (kW)
Conversion efficiency (%)
Heat-sink temperature (°C)
DC voltage (V)
DC ripple (% of DC voltage)