Demo with a simulated fleet: customers are invented and inverter data comes from a physics simulator. The analysis and the AI model run live on that data.
Fleet health

Tanja Harms

Early warning

26203 Wardenburg · 9.85 kWp · Kostal PIKO 8.3 (8.3 kW) · data from PIKO Solar Portal · S-0119

Result of the last 14 days
Cooling fault pattern, confirmed by physics checks
Health score
38

Suggested contact: Service visit + replacement quote. Cooling fault pattern, confirmed by physics checks on the 14-year-old Kostal PIKO 8.3. Estimated chance of failure within 12 months: 35 %.

  • A full failure would cost the customer about €180 for every month without production (yearly average).
  • The inverter still works. The customer has noticed nothing, so there is no pressure in the call.
  • Planned swap about €2,160 instead of an emergency call later.
  • Bring the evidence: the system page shows measured against expected values.
14.1 yrs
inverter age
Installed 17 Oct 2012
35 %
failure risk, next 12 months
Age curve from field data, adjusted by health
Expired
warranty left
5 years, ends 17 Oct 2017
6.1 years
EEG payment left
18.36 ct/kWh until 31 Dec 2032

Physics checks

Six rule families on the last 14 days of 5-minute values. No training data involved.

  • Operating state and limits
    No feed-in during 0.0 % of sunny samples · grid 225–235 V · heat sink max 50 °C
  • Power balance
    Conversion efficiency 95.0 % · +0.26 points extra loss vs datasheet curve
  • Thermal behaviour
    30.6 % of loaded samples hotter than the thermal model allows (up to +5 K)
  • Irradiance consistency
    Performance ratio 89 % (expected 70–100 %)
  • DC-side stability
    Ripple 0.89× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
  • Data quality
    99.9 % of expected samples received (1,256 values)

AI model

Fault class from the gap between measured values and the LSTM's healthy prediction.

  • Healthy0 %
  • Capacitor aging0 %
  • Cooling fault100 %
  • IGBT degradation0 %
  • MPPT fault0 %
  • Hard fault0 %

Estimated progression: 72 % of the way to failure-level symptoms.

Evidence check

ConsistentEarly warning

Physics checks confirm the AI alert.

Daily drift from healthy behaviour

Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.

5-minute values

19.3 kWh that day
AC power (kW)
Conversion efficiency (%)
Heat-sink temperature (°C)
DC voltage (V)
DC ripple (% of DC voltage)