Fleet health
Thomas Claaßen
Healthy26655 Westerstede · 5.17 kWp · Fronius Symo GEN24 5.0 Plus (5.0 kW) · data from Solar.web · S-0101
Result of the last 14 days
Behaves like a healthy inverter
Health score
1003.7 yrs
inverter age
Second inverter, installed 1 Mar 2023
2 %
failure risk, next 12 months
Age curve from field data, adjusted by health
15 months
warranty left
5 years, ends 1 Mar 2028
5.1 years
EEG payment left
28.74 ct/kWh until 31 Dec 2031
Physics checks
Six rule families on the last 14 days of 5-minute values. No training data involved.
- Operating state and limitsNo feed-in during 0.0 % of sunny samples · grid 226–235 V · heat sink max 28 °C
- Power balanceConversion efficiency 96.8 % · −0.14 points extra loss vs datasheet curve
- Thermal behaviour0.0 % of loaded samples hotter than the thermal model allows
- Irradiance consistencyPerformance ratio 87 % (expected 70–100 %)
- DC-side stabilityRipple 0.99× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
- Data quality100.0 % of expected samples received (1,257 values)
AI model
Fault class from the gap between measured values and the LSTM's healthy prediction.
- Healthy100 %
- Capacitor aging0 %
- Cooling fault0 %
- IGBT degradation0 %
- MPPT fault0 %
- Hard fault0 %
Evidence check
No alertHealthy
The AI model raised no alert.
Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.