Fleet health
Hauke Ihnen
Healthy26931 Elsfleth · 11.03 kWp · Fronius IG Plus 125 V (10.0 kW) · data from Solar.web · S-0051
Result of the last 14 days
Behaves like a healthy inverter
Health score
100Suggested contact: Hybrid inverter + battery. The 16-year-old Fronius IG Plus 125 V is beyond the typical service life. Chance of failure within 12 months: 6 %. The tariff ends in 2030, so one visit can cover inverter and battery.
- The inverter is 16 years old. In the field, about one in three fails within 15 years.
- From 2031 without changes: about €630 per year at market value.
- With a battery and self-consumption: about €1,650 per year in saved electricity and feed-in.
16.0 yrs
inverter age
Installed 8 Nov 2010
6 %
failure risk, next 12 months
Age curve from field data, adjusted by health
Expired
warranty left
5 years, ends 8 Nov 2015
4.1 years
EEG payment left
33.03 ct/kWh until 31 Dec 2030
Physics checks
Six rule families on the last 14 days of 5-minute values. No training data involved.
- Operating state and limitsNo feed-in during 0.0 % of sunny samples · grid 225–237 V · heat sink max 34 °C
- Power balanceConversion efficiency 94.4 % · −0.04 points extra loss vs datasheet curve
- Thermal behaviour0.0 % of loaded samples hotter than the thermal model allows
- Irradiance consistencyPerformance ratio 90 % (expected 70–100 %)
- DC-side stabilityRipple 1.00× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
- Data quality100.0 % of expected samples received (1,257 values)
AI model
Fault class from the gap between measured values and the LSTM's healthy prediction.
- Healthy100 %
- Capacitor aging0 %
- Cooling fault0 %
- IGBT degradation0 %
- MPPT fault0 %
- Hard fault0 %
Evidence check
No alertHealthy
The AI model raised no alert.
Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.