Fleet health
Bernd Meinen
Healthy26121 Oldenburg · 12.86 kWp · Huawei SUN2000-10KTL-M1 (10.0 kW) · data from FusionSolar · S-0049
Result of the last 14 days
Behaves like a healthy inverter
Health score
1007.3 yrs
inverter age
Second inverter, installed 18 Aug 2019
3 %
failure risk, next 12 months
Age curve from field data, adjusted by health
2.7 years
warranty left
10 years, ends 18 Aug 2029
4.1 years
EEG payment left
34.05 ct/kWh until 31 Dec 2030
Physics checks
Six rule families on the last 14 days of 5-minute values. No training data involved.
- Operating state and limitsNo feed-in during 0.0 % of sunny samples · grid 227–236 V · heat sink max 43 °C
- Power balanceConversion efficiency 97.9 % · +0.14 points extra loss vs datasheet curve
- Thermal behaviour0.0 % of loaded samples hotter than the thermal model allows
- Irradiance consistencyPerformance ratio 89 % (expected 70–100 %)
- DC-side stabilityRipple 1.01× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
- Data quality99.4 % of expected samples received (1,250 values)
AI model
Fault class from the gap between measured values and the LSTM's healthy prediction.
- Healthy98.7 %
- Capacitor aging0 %
- Cooling fault1.0 %
- IGBT degradation0 %
- MPPT fault0 %
- Hard fault0 %
Evidence check
No alertHealthy
The AI model raised no alert.
Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.