Fleet health

Petra Hoffmann

Early warning

26919 Brake · 7.38 kWp · Fronius IG Plus 75 V (6.0 kW) · data from Solar.web · S-0036

Result of the last 14 days
IGBT degradation pattern, confirmed by physics checks
Health score
48

Suggested contact: Service visit + replacement quote. IGBT degradation pattern, confirmed by physics checks on the 16-year-old Fronius IG Plus 75 V. Estimated chance of failure within 12 months: 35 %.

  • A full failure would cost the customer about €220 for every month without production (yearly average).
  • The inverter still works. The customer has noticed nothing, so there is no pressure in the call.
  • Planned swap about €1,880 instead of an emergency call later.
  • Bring the evidence: the system page shows measured against expected values.
16.6 yrs
inverter age
Installed 2 Apr 2010
35 %
failure risk, next 12 months
Age curve from field data, adjusted by health
Expired
warranty left
10 years, ends 2 Apr 2020
4.1 years
EEG payment left
39.14 ct/kWh until 31 Dec 2030

Physics checks

Six rule families on the last 14 days of 5-minute values. No training data involved.

  • Operating state and limits
    No feed-in during 0.0 % of sunny samples · grid 227–235 V · heat sink max 41 °C
  • Power balance
    Conversion efficiency 92.5 % · +1.60 points extra loss vs datasheet curve
  • Thermal behaviour
    0.0 % of loaded samples hotter than the thermal model allows
  • Irradiance consistency
    Performance ratio 90 % (expected 70–100 %)
  • DC-side stability
    Ripple 1.02× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
  • Data quality
    100.0 % of expected samples received (1,257 values)

AI model

Fault class from the gap between measured values and the LSTM's healthy prediction.

  • Healthy0 %
  • Capacitor aging0 %
  • Cooling fault0 %
  • IGBT degradation100 %
  • MPPT fault0 %
  • Hard fault0 %

Estimated progression: 59 % of the way to failure-level symptoms.

Evidence check

ConsistentEarly warning

Physics checks confirm the AI alert.

Daily drift from healthy behaviour

Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.

5-minute values

13.7 kWh that day
AC power (kW)
Conversion efficiency (%)
Heat-sink temperature (°C)
DC voltage (V)
DC ripple (% of DC voltage)