Demo with a simulated fleet: customers are invented and inverter data comes from a physics simulator. The analysis and the AI model run live on that data.
Fleet health

Petra Neumann

Healthy

26931 Elsfleth · 5.58 kWp · Fronius IG 50 (5.0 kW) · data from Solar.web · S-0021

Result of the last 14 days
Behaves like a healthy inverter
Health score
100

Suggested contact: Hybrid inverter + battery. The 16-year-old Fronius IG 50 is beyond the typical service life. Chance of failure within 12 months: 6 %. The tariff ends in 2029, so one visit can cover inverter and battery.

  • The inverter is 16 years old. In the field, about one in three fails within 15 years.
  • From 2030 without changes: about €320 per year at market value.
  • With a battery and self-consumption: about €1,340 per year in saved electricity and feed-in.
17.0 yrs
inverter age
Installed 9 Dec 2009
6 %
failure risk, next 12 months
Age curve from field data, adjusted by health
Expired
warranty left
5 years, ends 9 Dec 2014
3.1 years
EEG payment left
43.01 ct/kWh until 31 Dec 2029

Physics checks

Six rule families on the last 14 days of 5-minute values. No training data involved.

  • Operating state and limits
    No feed-in during 0.0 % of sunny samples · grid 227–236 V · heat sink max 32 °C
  • Power balance
    Conversion efficiency 92.5 % · −0.41 points extra loss vs datasheet curve
  • Thermal behaviour
    0.0 % of loaded samples hotter than the thermal model allows
  • Irradiance consistency
    Performance ratio 87 % (expected 70–100 %)
  • DC-side stability
    Ripple 0.98× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
  • Data quality
    100.0 % of expected samples received (1,257 values)

AI model

Fault class from the gap between measured values and the LSTM's healthy prediction.

  • Healthy100 %
  • Capacitor aging0 %
  • Cooling fault0 %
  • IGBT degradation0 %
  • MPPT fault0 %
  • Hard fault0 %

Evidence check

No alertHealthy

The AI model raised no alert.

Daily drift from healthy behaviour

Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.

5-minute values

12.1 kWh that day
AC power (kW)
Conversion efficiency (%)
Heat-sink temperature (°C)
DC voltage (V)
DC ripple (% of DC voltage)