Fleet health
Stefan Meinen
Healthy26931 Elsfleth · 6.04 kWp · KACO Powador 5002 (5.0 kW) · data from blueplanet web · S-0018
Result of the last 14 days
Behaves like a healthy inverter
Health score
100Suggested contact: Hybrid inverter + battery. The 18-year-old KACO Powador 5002 is beyond the typical service life. Chance of failure within 12 months: 7 %. The tariff ends in 2028, so one visit can cover inverter and battery.
- The inverter is 18 years old. In the field, about one in three fails within 15 years.
- From 2029 without changes: about €340 per year at market value.
- With a battery and self-consumption: about €1,360 per year in saved electricity and feed-in.
18.6 yrs
inverter age
Installed 20 Apr 2008
7 %
failure risk, next 12 months
Age curve from field data, adjusted by health
Expired
warranty left
7 years, ends 20 Apr 2015
2.1 years
EEG payment left
46.75 ct/kWh until 31 Dec 2028
Physics checks
Six rule families on the last 14 days of 5-minute values. No training data involved.
- Operating state and limitsNo feed-in during 0.0 % of sunny samples · grid 226–236 V · heat sink max 31 °C
- Power balanceConversion efficiency 94.3 % · +0.04 points extra loss vs datasheet curve
- Thermal behaviour0.0 % of loaded samples hotter than the thermal model allows
- Irradiance consistencyPerformance ratio 93 % (expected 70–100 %)
- DC-side stabilityRipple 0.91× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
- Data quality99.6 % of expected samples received (1,252 values)
AI model
Fault class from the gap between measured values and the LSTM's healthy prediction.
- Healthy99.3 %
- Capacitor aging0 %
- Cooling fault0 %
- IGBT degradation0.6 %
- MPPT fault0 %
- Hard fault0 %
Evidence check
No alertHealthy
The AI model raised no alert.
Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.