Demo with a simulated fleet: customers are invented and inverter data comes from a physics simulator. The analysis and the AI model run live on that data.
Fleet health

Elke Cordes

Healthy

26197 Großenkneten · 6.40 kWp · SMA Sunny Mini Central 6000A (6.0 kW) · data from Sunny Portal · S-0009

Result of the last 14 days
Behaves like a healthy inverter
Health score
100

Suggested contact: Hybrid inverter + battery. The 19-year-old SMA Sunny Mini Central 6000A is beyond the typical service life. Chance of failure within 12 months: 7 %. The tariff ends in 2027, so one visit can cover inverter and battery.

  • The inverter is 19 years old. In the field, about one in three fails within 15 years.
  • From 2028 without changes: about €360 per year at market value.
  • With a battery and self-consumption: about €1,380 per year in saved electricity and feed-in.
19.6 yrs
inverter age
Installed 6 May 2007
7 %
failure risk, next 12 months
Age curve from field data, adjusted by health
Expired
warranty left
5 years, ends 6 May 2012
13 months
EEG payment left
49.21 ct/kWh until 31 Dec 2027

Physics checks

Six rule families on the last 14 days of 5-minute values. No training data involved.

  • Operating state and limits
    No feed-in during 0.0 % of sunny samples · grid 227–235 V · heat sink max 33 °C
  • Power balance
    Conversion efficiency 94.3 % · +0.01 points extra loss vs datasheet curve
  • Thermal behaviour
    0.0 % of loaded samples hotter than the thermal model allows
  • Irradiance consistency
    Performance ratio 90 % (expected 70–100 %)
  • DC-side stability
    Ripple 0.90× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
  • Data quality
    100.0 % of expected samples received (1,257 values)

AI model

Fault class from the gap between measured values and the LSTM's healthy prediction.

  • Healthy100 %
  • Capacitor aging0 %
  • Cooling fault0 %
  • IGBT degradation0 %
  • MPPT fault0 %
  • Hard fault0 %

Evidence check

No alertHealthy

The AI model raised no alert.

Daily drift from healthy behaviour

Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.

5-minute values

16.4 kWh that day
AC power (kW)
Conversion efficiency (%)
Heat-sink temperature (°C)
DC voltage (V)
DC ripple (% of DC voltage)