Demo with a simulated fleet: customers are invented and inverter data comes from a physics simulator. The analysis and the AI model run live on that data.
Fleet health

Helga und Werner Albers

Healthy

26203 Wardenburg · 5.75 kWp · Fronius Symo 5.0-3-M (5.0 kW) · data from Solar.web · S-0003

Result of the last 14 days
Behaves like a healthy inverter
Health score
100

Suggested contact: Battery. The feed-in tariff of 51.80 ct/kWh ends on 31 Dec 2026. After that the owner earns only the market value, so self-consumption becomes the better deal.

  • Today: about €2,830 feed-in payment per year at 51.80 ct/kWh.
  • From 2027 without changes: about €330 per year at market value.
  • With a battery and self-consumption: about €1,350 per year in saved electricity and feed-in.
10.5 yrs
inverter age
Second inverter, installed 26 May 2016
4 %
failure risk, next 12 months
Age curve from field data, adjusted by health
Expired
warranty left
7 years, ends 26 May 2023
38 days
EEG payment left
51.80 ct/kWh until 31 Dec 2026

Physics checks

Six rule families on the last 14 days of 5-minute values. No training data involved.

  • Operating state and limits
    No feed-in during 0.0 % of sunny samples · grid 225–233 V · heat sink max 35 °C
  • Power balance
    Conversion efficiency 97.4 % · −0.03 points extra loss vs datasheet curve
  • Thermal behaviour
    0.0 % of loaded samples hotter than the thermal model allows
  • Irradiance consistency
    Performance ratio 90 % (expected 70–100 %)
  • DC-side stability
    Ripple 1.05× nominal · 0.0 % of samples more than 6 % off the expected MPP voltage
  • Data quality
    99.0 % of expected samples received (1,244 values)

AI model

Fault class from the gap between measured values and the LSTM's healthy prediction.

  • Healthy99.4 %
  • Capacitor aging0 %
  • Cooling fault0.5 %
  • IGBT degradation0 %
  • MPPT fault0 %
  • Hard fault0 %

Evidence check

No alertHealthy

The AI model raised no alert.

Daily drift from healthy behaviour

Gap between measured values and the AI model, in units of normal day-to-day scatter. Around 1 is normal. Dark days carry no information and are left out.

5-minute values

15.4 kWh that day
AC power (kW)
Conversion efficiency (%)
Heat-sink temperature (°C)
DC voltage (V)
DC ripple (% of DC voltage)